Testing accessories · Bending tests
Clip gauge for bending tests
High-precision measuring instrument for determining crack opening (CMOD – Crack Mouth Opening Displacement) in bending tests on centre-notched concrete beams, according to EN 14651.
Useful stroke
8 mm
Resolution
0.0001 mm
Standard
EN 14651

Useful stroke
8 mm
8
mm
Total useful stroke
0.0001
mm
Resolution
350
Ω
Bridge resistance
2
mV/V
Sensitivity (± 0.1)
CMOD measurement
Crack opening, measured accurately
The clip gauge measures crack opening (CMOD) during bending tests on centre-notched concrete beams. It is supplied complete with 20 adhesive base plates for direct application to the specimen.
CMOD measurement
Determines crack opening in bending tests on centre-notched concrete beams.
Full-bridge strain gauge
Strain gauge measurement technology (full bridge), bridge resistance 350 Ω.
8 mm useful stroke
Total useful stroke of 8 mm with 0.0001 mm resolution.
20 adhesive base plates included
Supplied complete with 20 adhesive base plates for direct application to the concrete specimen.
Quick installation
Quick installation and removal, without damaging the specimen surface.
Analogue output
Analogue output compatible with data acquisition systems with strain gauge input.
Technical features
Technical features
Specification
Clip Gage
Maximum stroke
8 mm
Resolution
0.0001 mm
Measurement technology
Strain gauge bridge (full bridge)
Bridge resistance
350 Ω
Sensitivity
2 mV/V ± 0.1
Output
0 – 10 V, optional 2 mV/V
Overall size
80 × 350 mm
Useful length
600 mm
Power supply
2 mV/V
Reference standards
Compliant with testing standards
Description
STANDARD
Bending tests on centre-notched concrete beams: measurement of crack opening (CMOD)
EN 14651
frequently asked questions
Everything about this product
What does the clip gauge measure?
Crack opening (CMOD – Crack Mouth Opening Displacement) during bending tests on centre-notched concrete beams, according to EN 14651.
How is it applied to the specimen?
With the 20 adhesive base plates supplied, for direct application to the concrete specimen: installation and removal are quick and do not damage the surface.
Which acquisition systems is it compatible with?
The analogue output is compatible with data acquisition systems with strain gauge input.
Contact
Quick quote
Tell us the required energy, the reference standard and the type of specimen: our technicians will recommend the most suitable model and the useful accessories, with a reply within 24 working hours.
MB
Marco Bianchi · Applications manager
Replies within 24 working hours
Quality and accreditations
ISO 9001:2015
Quality system
CE marking
European conformity
EN ISO 7500-1
Force calibration
Made in Italy
In-house assembly