Testing accessories · Bending tests

Clip gauge for bending tests

High-precision measuring instrument for determining crack opening (CMOD – Crack Mouth Opening Displacement) in bending tests on centre-notched concrete beams, according to EN 14651.

Useful stroke

8 mm

Resolution

0.0001 mm

Standard

EN 14651

Useful stroke

8 mm

8

mm

Total useful stroke

0.0001

mm

Resolution

350

Ω

Bridge resistance

2

mV/V

Sensitivity (± 0.1)

CMOD measurement

Crack opening, measured accurately

The clip gauge measures crack opening (CMOD) during bending tests on centre-notched concrete beams. It is supplied complete with 20 adhesive base plates for direct application to the specimen.

CMOD measurement

CMOD measurement

Determines crack opening in bending tests on centre-notched concrete beams.

Full-bridge strain gauge

Full-bridge strain gauge

Strain gauge measurement technology (full bridge), bridge resistance 350 Ω.

8 mm useful stroke

8 mm useful stroke

Total useful stroke of 8 mm with 0.0001 mm resolution.

20 adhesive base plates included

20 adhesive base plates included

Supplied complete with 20 adhesive base plates for direct application to the concrete specimen.

Quick installation

Quick installation

Quick installation and removal, without damaging the specimen surface.

Analogue output

Analogue output

Analogue output compatible with data acquisition systems with strain gauge input.

Technical features

Technical features

Specification

Clip Gage

Maximum stroke

8 mm

Resolution

0.0001 mm

Measurement technology

Strain gauge bridge (full bridge)

Bridge resistance

350 Ω

Sensitivity

2 mV/V ± 0.1

Output

0 – 10 V, optional 2 mV/V

Overall size

80 × 350 mm

Useful length

600 mm

Power supply

2 mV/V

Reference standards

Compliant with testing standards

Description

STANDARD

Bending tests on centre-notched concrete beams: measurement of crack opening (CMOD)

EN 14651

frequently asked questions

Everything about this product

What does the clip gauge measure?

Crack opening (CMOD – Crack Mouth Opening Displacement) during bending tests on centre-notched concrete beams, according to EN 14651.

How is it applied to the specimen?

With the 20 adhesive base plates supplied, for direct application to the concrete specimen: installation and removal are quick and do not damage the surface.

Which acquisition systems is it compatible with?

The analogue output is compatible with data acquisition systems with strain gauge input.

Contact

Quick quote

Tell us the required energy, the reference standard and the type of specimen: our technicians will recommend the most suitable model and the useful accessories, with a reply within 24 working hours.

MB

Marco Bianchi · Applications manager

Replies within 24 working hours

Quality and accreditations

R

ISO 9001:2015

Quality system

CE marking

European conformity

EN ISO 7500-1

Force calibration

Made in Italy

In-house assembly